Receiver Configuration Dialog - Bosch Security Escort SE2000 Series Training Manual

Hide thumbs Also See for Security Escort SE2000 Series:
Table of Contents

Advertisement

106 en | Troubleshooting transponders, points, receivers, and alert units
Symptoms
Receiver LEDs not working.
Receiver's sounder not
operating.
Tab. 7.8: EA102 receiver issues
7.4

Receiver configuration dialog

Once the receiver and alert unit data for a transponder has been entered into the
Transponder Database, this dialog is used to verify that each receiver is working and is
properly addressed in the database. This setup tool identifies errors in the address switch
settings of receivers and alert units as well as data entry errors in the Transponder Database.
To Confirm the RF Reception
To confirm the RF reception, LED, sounder operation and location of each receiver, select
Receiver configuration from the Setup menu. The following dialog appears:
2017.08 | V2.18.1.0 | DOC
Probable Cause
LEDs not positioned behind
viewing lens.
Jumpers in "OFF" position on
receiver.
Bad receiver.
Jumper in "OFF" position on
receiver.
"Run Silent" is turned on in
the Central Console software.
Bad receiver.
Training Manual
Security Escort
Possible Solutions
Remove cover, straighten
LEDs, replace cover carefully
so LEDs are positioned
behind viewing lens. Use
maintenance transmitter on
test and alarm after installing
cover to check visibility of
LED.
Remove cover, check jumpers
to right of sounder above red
LED and make sure jumpers
P2 and P3 are "ON".
After performing the steps
above and LEDs still do not
operate on test or alarm,
replace the receiver.
Remove the cover, check
jumper to right of sounder
above red LED and make sure
jumper P1 is "ON".
At the Central Console, select
menu Setup > Transponder
Parameter dialog and un-
check the Run Silent
checkbox.
If the sounder still does not
operate after performing the
steps above, replace the
receiver.
Robert Bosch (SEA) Pte Ltd