Security Escort
Data fields in required
order
Alert Unit 2
Alert Unit 2 Point
Alert Unit 3
Alert Unit 3 Point
Alert Unit Test
Alert Unit Test Point
Point Location Text
Map X Position
Map Y Position
Sensitivity Adjust
Bitmap Number
7.13.2

XML file format

XML or Extensible Markup Language is a markup language used to store and transport data in
both human-and machine-readable format.
Notice!
Area data of the transponders is supported in the XML file format.
Robert Bosch (SEA) Pte Ltd
Troubleshooting transponders, points, receivers, and alert units | en 163
Excel Column Restrictions
AOY
This field contains the Transponder ID of the
alert unit. If this is not configured, this field is 0.
This field should contain only numeric ASCII
characters.
AOZ
This field contains the alert unit point number. If
this is not configured, this field is -1. This field
should contain only numeric ASCII characters.
APA
This field contains the Transponder ID of the
alert unit. If this is not configured, this field is 0.
This field should contain only numeric ASCII
characters.
APB
This field contains the alert unit point number. If
this is not configured, this field is -1. This field
should contain only numeric ASCII characters.
APC
This field contains the Transponder ID of the
alert unit. If this is not configured, this field is 0.
This field should contain only numeric ASCII
characters.
APD
This field contains the alert unit point number. If
this is not configured, this field is -1. This field
should contain only numeric ASCII characters.
APE
This field may be up to 100 characters. This field
may contain any printable ASCII character
except the '?'.
APF
X position of the point on the map. Default is 0.
This field should contain only numeric ASCII
characters.
APG
Y position of the point on the map. Default is 0.
This field should contain only numeric ASCII
characters.
APH
0-99. This field should contain only numeric
ASCII characters.
API
0-99. This field should contain only numeric
ASCII characters.