en | System wiring
Figure 4.5: Address Switch
There are two groups of jumpers on the EA102A-304 Receiver. The first group contains
jumpers P1 through P3. The second contains jumpers P4 through P8. The function of each
jumper is indicated in the table below:
Jumper
P1*
P2*
P3*
P4**
P5**
P6**
P7**
P8
Notice!
* Remove jumpers P1, P2, and P3 when installed in an outdoor enclosure.
** Remove jumpers P4, P5, P6, and P7 for normal operation.
Test mode
The module goes into test mode when jumper P4 is in place (jumper P5 removed). In this
mode, all test and alarm receptions will be sounded.
Notice!
The sounder and LEDs (jumpers P1, P2, and P3) must also be enabled to operate the test
mode.
Each receiver should be tested using the following method (test only one receiver at a time):
1.
2.
2017.08 | V2.18.1.0 | DOC
Operation with Jumper in Place
Sounder is enabled
Green LED is enabled
Red LED is enabled
Test Mode is enabled
Receiver Spacing Mode is enabled
Left Antenna is disabled
Right Antenna is disabled
Do not place a jumper across these pins.
Enable the test mode by placing the jumper P4 across both pins (jumper P5 removed).
The red LED will turn ON and stay ON during the test.
The green LED will flicker if the receiver is connected to a working transponder.
There will be no data transmitted to the central station.
The central station will receive a "not responding" failure.
Activate the transmitter from at least five different locations near the receiver.
The LEDs will respond to a received transmission.