Bosch Security Escort SE2000 Series Training Manual page 108

Hide thumbs Also See for Security Escort SE2000 Series:
Table of Contents

Advertisement

108 en | Troubleshooting transponders, points, receivers, and alert units
Security Escort
Figure 7.4: Receiver Configuration Dialog
Take the maintenance transmitter and go to the selected receiver. The red and green light
should be lit up when you arrive at the first receiver location. Transmit an alarm from the
maintenance transmitter. The receiver should activate by blinking the red lights and sounding
the sounder (if the sounder jumper is in place on the receiver).
This will confirm that the RF portion of the receiver is working and you are at the right
location. The software will then turn off the LEDs on the tested receiver. The receiver with the
next higher point number will be automatically selected and its red and green LEDs will light.
Proceed to that receiver and perform the same operation with an alarm on the maintenance
transmitter until the operation of all receivers has been confirmed and all receivers are
working and in their proper location on that transponder.
If the LEDs fail to light, the LED jumpers may be missing on that receiver, the receiver may be
set to the wrong address, or you may be at the wrong location. If the LEDs are lit but the
receiver fails to respond to the maintenance alarm, there may be a problem with the receiver
board or another receiver is receiving the signal stronger.
Repeat the above sequence starting with step 1 for all transponders and receivers in the
system.
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents