Receiver Configuration - Bosch Security Escort SE2000 Series Training Manual

Hide thumbs Also See for Security Escort SE2000 Series:
Table of Contents

Advertisement

Security Escort
[EE point info]
[EE point stat]
[EE point trouble]
[Bus micro revision]
[Last MUX message]
[EE counters]
[Save EE]
[Clear EE]
[Previous]
[Next]
[Cancel]
8.3.6

Receiver configuration

Once the receiver and alert unit data for a transponder has been entered into the
Transponder Database, this dialog is used to verify that each receiver is working and is
properly addressed in the database. This setup tool identifies errors in the address switch
settings of receivers and alert units as well as data entry errors in the Transponder Database.
Robert Bosch (SEA) Pte Ltd
Views the EEPROM image of point information.
Views the EEPROM image of point status.
Views the EEPROM image of point trouble.
Views the bus micro revision for the connected points.
Views the last MUX bus message received.
Views the EEPROM image of the process registers.
Saves the current RAM image to the EEPROM memory on the
transponder.
Clears the EEPROM memory on the transponder and resets the
transponder.
Returns to the previous transponder in the system.
Advances to the next transponder in the system.
Cancels the operation and closes the dialog window.