Table of Contents

Advertisement

CC880/LP880, SC8016
Operators Guide
Solution-16,
EN
Solution-16 Safecom

Advertisement

Table of Contents
loading

Summary of Contents for Bosch CC880/LP880, SC8016

  • Page 1 CC880/LP880, SC8016 Operators Guide Solution-16, Solution-16 Safecom...
  • Page 2: Copyright Notice

    This equipment is set up to carry out test calls at pre- determined times. Such test calls interrupt any other Bosch Security Systems Pty Ltd reserves the right to calls that may be set up on the line at the same time.
  • Page 3: Table Of Contents

    CC880/LP880, SC8016 | Operators Guide | EN | 3 Table of Contents 18.0 Testing............. 13 Introduction ............5 19.0 Event Memory Recall........13 Specifications ............ 5 20.0 Day Alarm ............13 Codepad Indicators.......... 5 21.0 Codepad ID and Buzzer Tone ..... 14 Zone Indicators..........
  • Page 4 CC880/LP880, SC8016 | Operators Guide | EN | 4 Tables Table 1: Specifications ..........5 Table 2: Zone Indicator........... 6 Table 3: AWAY Indicator........6 Table 4: STAY Indicator ......... 6 Table 5: MAINS Indicator ........7 Table 6: FAULT Indicator ........7 Table 7: Audible Indicators........
  • Page 5: Introduction

    CC880/LP880, SC8016 | Operators Guide | 1.0 Introduction EN | 5 1.0 Introduction The Austel permit issued for this product is subject to the following conditions: Congratulations on selecting the Solution-16 Control The Solution-16 Control Panel Panel to protect you and your property. Take time to...
  • Page 6: Zone Indicators

    CC880/LP880, SC8016 | Operators Guide | 3.0 Codepad Indicators EN | 6 Figure 3: CP5 Eight Zone LCD Codepad Table 2: Zone Indicator Zone Indicator Definition Zone is unsealed Zone is sealed Flashing Fast Zone is in alarm condition (0.25 sec. on/ 0.25 sec.
  • Page 7: System Disarmed

    CC880/LP880, SC8016 | Operators Guide | 4.0 Arming the System EN | 7 System Disarmed Table 7: Audible Indicators This indicator displays with the indicator when the system is disarmed. Audible Indicator Definition Once short beep A button was pressed on the...
  • Page 8: Forced Arming

    CC880/LP880, SC8016 | Operators Guide | 4.0 Arming the System EN | 8 If the Entry Guard Timer For STAY Mode 1 is Forced Arming programmed and a zone not automatically isolated is Forced arming arms the system when a zone is not triggered, the codepad beeps twice a second until the sealed.
  • Page 9: Programming Stay Mode 2 Zones

    CC880/LP880, SC8016 | Operators Guide | 5.0 Disarming the System EN | 9 6.0 Adding User Codes How to Arm the System in STAY Mode 2 Hold down the [0] button until two beeps are heard. Only the master code holder can add or change...
  • Page 10: Codepad Duress Alarm

    CC880/LP880, SC8016 | Operators Guide | 8.0 Codepad Duress Alarm EN | 10 8.0 Codepad Duress Alarm 9.0 Codepad Panic Alarm A codepad duress alarm is used as a silent hold-up An audible alarm activates when both the [1] and [3] alarm.
  • Page 11: Standard Isolating

    CC880/LP880, SC8016 | Operators Guide | 14.0 Fault Analysis Mode EN | 11 How to Determine the Type of System Fault 13.1 Standard Isolating To determine which system fault occurred, enter Standard isolating allows all operators to isolate fault analysis mode.
  • Page 12: Date And Time

    CC880/LP880, SC8016 | Operators Guide | 15.0 Date and Time EN | 12 2. Enter the day, month, year, hour, and minute Horn Speaker Fail (DD, MM, YY, HH, MM format) (for example, A horn speaker failure fault registers when the DD = day of the month, MM = month of the system detects that the horn speaker is disconnected.
  • Page 13: Reset Latching Outputs

    CC880/LP880, SC8016 | Operators Guide | 17.0 Reset Latching Outputs EN | 13 17.0 Reset Latching Outputs 19.0 Event Memory Recall This feature is only applicable if your installer Use this function to replay back the last 40 events programmed an output to latch (remain on) until you that occurred to the system.
  • Page 14: Codepad Id And Buzzer Tone

    CC880/LP880, SC8016 | Operators Guide | 21.0 Codepad ID and Buzzer Tone EN | 14 22.1.2 Area On/Off Indicators 21.0 Codepad ID and Buzzer The group of four AREA ON/OFF indicators display the status of each area. (For example, if an indicator Tone is displayed, that area is armed.
  • Page 15: Arm/Disarm All Areas At The Same Time

    CC880/LP880, SC8016 | Operators Guide | 23.0 Remote Arming By Telephone EN | 15 Example If the AREA DISPLAY displays number 2, all If your installer programs answering operations performed only operate Area 2. To machine bypass, call the control panel...
  • Page 16: Domestic Dialling

    CC880/LP880, SC8016 | Operators Guide | 25.0 Domestic Dialling EN | 16 How to Program Telephone Numbers 25.0 Domestic Dialling 1. Enter your four character master code, followed by [2] and the [#] button (for example, Use domestic dialling to call your mobile phone or a [2 5 8 0 2 #]).
  • Page 17: Domestic Voice Message Reporting

    CC880/LP880, SC8016 | Operators Guide | 26.0 Domestic Voice Message EN | 17 Reporting Zone Status 26.0 Domestic Voice Message The zone status display shows you the status of each zone (1 to 8). Table 15 describes what each number Reporting means when displayed on the zone status display.
  • Page 18: Basic Pager Display

    CC880/LP880, SC8016 | Operators Guide | 27.0 Basic Pager Reporting EN | 18 Figure 8: Basic Pager Display 01200000 9000 Zone Normal - 0 Alarm - 1 Zone Bypassed - 2 Zone Trouble - 3 Disarmed - 8 Armed - 9...
  • Page 19: Pet Pager Reporting

    CC880/LP880, SC8016 | Operators Guide | 28.0 PET Pager Reporting EN | 19 The following example shows how a single 28.0 PET Pager Reporting transmission is received on the PET pager. A similar message to the one below is seen when the The system can be configured by your security control panel is armed by User 1.
  • Page 20: Glossary Of Terms

    CC880/LP880, SC8016 | Operators Guide | 29.0 Glossary of Terms EN | 20 29.0 Glossary of Terms Table 19: Glossary of Terms Term Description 24-Hour Zones A monitored input programmed to trigger an alarm condition when violated when the system is armed or disarmed 24 hours a day.
  • Page 21: Mode 2

    CC880/LP880, SC8016 | Operators Guide | 29.0 Glossary of Terms EN | 21 Table 19: continued Term Description Phone Controller The phone controller can be used to turn your system on in AWAY Mode via the telephone by generating a tone.
  • Page 22: Installation Notes

    CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 22 30.0 Installation Notes Installation Company Technician’s Name Technician’s Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes Bosch Security Systems | 6/04 | 920036O.OG.162...
  • Page 23 CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 23 Zone Description Describe each zone and mark which zones were programmed to be automatically isolated in STAY Mode 1 or were programmed for day alarm operation. Isolated In...
  • Page 24 CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 24 User Code Names Master Master Code Code Default = 2580 User Code 1 User Code 17 User Code 2 User Code 18 User Code 3 User Code 19...
  • Page 25 CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 25 Entry/Exit Times Entry Timer 1 Exit Time Entry Timer 2 Entry Guard Time Entry Timer 3 Entry Timer 4 Arming Options Single Button Arming (AWAY/STAY) Forced Arming Single Button Disarming (STAY Mode)
  • Page 26 CC880/LP880, SC8016 | Operators Guide | 30.0 Installation Notes EN | 26 Communication Options Back To Base Reporting Panel Account Number Domestic Reporting Domestic Reporting – No Of Beeps Basic Pager Reporting PET Pager/SMS Reporting Remote Arming Allowed DTMF Command Module Fitted...
  • Page 27 CC880/LP880, SC8016 | Operators Guide | Index EN | 27 Index 24-Hour Zones ............19 Domestic Dialling ..........15 Acknowledging Domestic Calls...... 15 Disable............... 15 Adding User Codes ..........8 Programming Domestic Telephone Alarm Condition...........19 Numbers ............15 Answering Machine Bypass ........19 Duress Alarm............
  • Page 28 CC880/LP880, SC8016 | Operators Guide | Index EN | 28 Zone Indicators ..........13 STAY Mode 1 ..........7, 20 Medical Alarm ............9 Entry Guard Timer ..........7 Monitoring Station ..........19 STAY Mode 2 ..........7, 20 Entry Guard Timer ..........7 Programming Zones...........
  • Page 29 CC880/LP880, SC8016 | Operators Guide | Index EN | 29 Notes: Bosch Security Systems | 6/04 | 920036O.OG.162...
  • Page 30 CC880/LP880, SC8016 | Operators Guide | Index EN | 30 Notes: Bosch Security Systems | 6/04 | 920036O.OG.162...
  • Page 31 CC880/LP880, SC8016 | Operators Guide | Index EN | 31 Notes: Bosch Security Systems | 6/04 | 920036O.OG.162...
  • Page 32 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 © 2003 Bosch Security Systems 920036O 4998152460B Issue 1.62...

This manual is also suitable for:

Cc880Lp880

Table of Contents