Description
An Alert Unit is a control module that communicates with the Transponder on the MUX Bus. In
most installations, it is used to activate Siren/Strobe units or other switched devices in the
event of an alarm. The Alert Unit also reports tampering, AC power loss, and backup battery
level to the Transponder.
Installation
The Alert Unit may be housed in either a metal indoor enclosure or an outdoor enclosure
(similar to the Outdoor Receiver enclosure), depending on the application. The Strobe/Siren
units are always mounted in outdoor locations.
Function
The Alert Unit has backup battery power in addition to AC power. The Alert Unit Driver
contains a microprocessor that communicates with the Transponder for Strobe and Siren
commands, status reports, and trouble indications. The troubles monitored are "Tamper",
"Loss of AC Power", and "Low Battery".
Test Acknowledgment
In addition to the function of attracting attention in the event of an emergency, the Strobe unit
is used to acknowledge a successful test of a Transmitter. The Alert Unit can be configured to
cause a Siren to emit a short tone and the strobe to flash for a successful Transmitter test.
Function During an Alarm
In the event of an alarm, the Alert Unit receives a signal from the Transponder and begins
powering the Siren/Strobe (or other switched device). The Siren/Strobe will be active until
the alarm is restored at the Central Console.
Robert Bosch (SEA) Pte Ltd
Indoor and Outdoor enclosures available.
AC powered with battery backup.
Activated on command from the Central Station through the Transponder.
Reports tampering, AC power loss, backup battery power to the Transponder, and output
status.