7.1 Peripheral Equipment Mounts

7 System Application

7.1
Peripheral Equipment Mounts
The peripheral equipment mounts are fixed on the upper arm for easier installation of
the user's system application as shown in " Fig. 14 Installing Peripheral Equipment Mounts ".
When peripheral equipment is attached to the U-axis, the following conditions should be
observed.
7.1.1

Allowable Load

The allowable load on the U-axis is a maximum of 31 kg, including the wrist load.
For instance, when the mass installed in the wrist point is 20 kg, the mass which can be
installed on the upper arm is 11 kg.
7.1.2

Installation Position

There is a limitation on the installation position.
" Fig. 15 Allowable Load on U-axis " shows the distance between the center of U-axis rotation
and the load gravity.
Limited dimension
of
Z-coordinate:
400 at a maximum
Center of U-axis rotation
A
Z-coordinate
W2
direction
X-coordinate
direction
Fig. 14 Installing Peripheral Equipment Mounts
7-1
W1
70
View A
Units: mm