Figure 13: Troubleshooting workflow

Checking alerts

The Remote Web Console main window displays an icon indicating whether service information
messages (SIMs) occurred in the storage system.
To check details of a SIM:
Procedure
1. In the Remote Web Console main window, click Alert. The Alerts window opens.
Figure 14: Alert icon on Remote Web Console main window
2. To check the details of each alert, select and right-click one row, and then, click Detail in the pop-up
menu. The detail dialog box opens.
3. If the following SIM reference codes appear, you must resolve the error (XXX indicates the pool ID):
a. 601XXX, 602XXX, 602FFE, and 624000 (for Fast Snap)
b. 601XXX, 602XXX, and 602FFF (for Snapshot)