AEMC OX III Series User Manual page 81

100/200mhz portable oscilloscopes
Table of Contents

Advertisement

Oscilloscope Mode - The "Horizontal" Menu
Oscilloscope Mode (cont'd)
"EXTENDED
ACQUISITION
MEMORY"
option operation
Shop for AEMC products online at:
SCOPIX
The finite duration of the study interval results in a convolution in the signal
frequency domain with a function sinx/x.
This convolution modifies the graphic representation of the FFT because
of the lateral lobes characteristic of the sinx/x function (unless the study
interval contains an whole number of periods).
Four types of window selections are available: the menus appear directly
on selection of the FFT menu.
Type of window
Rectangular window
Hanning window
Hamming window
Blackman window
Effects of under-sampling on frequency representation:
If the sampling frequency is not correctly adjusted (less than or twice the
maximum frequency of the signal to be measured), the high-frequency
components will be under-sampled and appear in the graphic
representation of the FFT by symmetry (aliasing).
The "Autoset" function is active. This prevents the phenomenon above
and adapts the horizontal scale: the representation is more legible.
The "Zoom" function is active.
The " " symbol in front of one of the options indicates the function
selected.
If the "EXTENDED ACQUISITION MEMORY" option is installed
(see §. Menu " ? "
"Options"):
• The acquisition memory is extended from 2,500 samples to 50,000
samples.
• On the time base range [1 ns, 5 ms], the signal image is obtained by the
aggregate of several acquisitions and reconstruction. Deactivate the
"HORIZ "
"Repetitive Signal" option if the signal observed is not
periodical, acquired and synchronous with the trigger.
• On the time base range [10 ms, 200 s], 50,000 samples are obtained in
one acquisition.
ShopAEMC
www.
Width of main
Max. amplitude of
lobe
(compared with main
- 13 dB
- 32 dB
- 43 dB
- 94 dB
.com
1.877.766.5412
secondary lobe
lobe)
4 π/N
8 π/N
8 π/N
12 π/N
IV - 81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ox 7202 iiiOx 7102 iiiOx 7104 iiiOx 7204 iii

Table of Contents