AEMC OX III Series User Manual page 209

100/200mhz portable oscilloscopes
Table of Contents

Advertisement

Technical Specifications
Technical Specifications (cont'd)
Accessories
HX0072 - AmpFLEX Probe
HX0073 - MiniAmpFLEX
Shop for AEMC products online at:
SCOPIX
Standards applied
Reference conditions
Use conditions
Range for use
Specified range
Accuracy in the
measurement range
50 Hz dephasing
Residual current
at I = 0 A (noise)
Bandwidth at -3 dB
Power-up and to-idle
time
Residual DC current
Delay time
Frequency derating
Electromagnetic
immunity at 10 V/m
Operating temperature
Standards applied
Probe
Reference conditions
Use conditions
Range for use
Specified range
Accuracy in the
measurement range
50 Hz dephasing
Residual current at
I = 0 A (noise)
BW min.at -3 dB
Power-up and to-idle
time
Residual DC current
Delay time
Frequency derating
Electromagnetic
immunity at 10 V/m
ShopAEMC
Operating temperature
www.
IEC 61010-2-032 : 2002
EN 61326-1 (07/1997) + A1 (10/1998) + A2 (09/2001)
Only one conductor inserted in the flexible toroid
Conductor position:
Clamping :
Temperature :
Relative humidity:
Frequency range:
Start-up before measurement:
External DC magnetic field:
No external AC magnetic field
No external electric field
Sinusoidal signal
Altitude < 2000 m, indoors
from 1 A to 3500 A
RMS
from 5 A to 3000 A
RMS
1 % ± 0.5 A
1.3° max. (1° typ.)
1.5 A
max. (0.5 A
typ.)
RMS
RMS
10 Hz to 200 kHz
1.5 µs
20 A max. (invisible with AC coupling)
1.2 µs max.
3000 A if 10 Hz < Freq. < 10 kHz
50A if Freq. = 200 kHz
error < 3 % of measurement extent
-10°C to +55°C
IEC 61010-2-032 : 2002
EN 61326-1 (07/1997) + A1 (10/1998) + A2 (09/2001)
Only one conductor inserted in the flexible toroid centred
Conductor position:
Clamping :
Temperature :
Relative humidity:
Frequency range:
Start-up before measurement:
External DC magnetic field:
No external AC magnetic field
No external electric field
Sinusoidal signal
Altitude < 2000 m, indoors
from 0.2 A to 350 A
RMS
from 1 A to 300 A
RMS
1 % ± 70 mA
1.3° max. (1° typ.)
0.2 A
max. (0.1 A
typ.)
RMS
RMS
from 10 Hz to 2.5 MHz (from 10 Hz to 3 MHz typ.)
< 110 ns
2 A max. (invisible with AC coupling)
600 ns max.
300 A if 10Hz < Freq. < 100 kHz
10 A if Freq. > 1 MHz
error < 3 % of measurement extent
-10°C to +55°C
.com
centred
∅ 240 mm
from 18°C to 28°C
from 20 % to 75 %
40 Hz to 400 Hz
1min
< 40 A/m
centred
∅ 35 mm
from 18°C to 28°C
from 20 % to 75 %
40 Hz to 400 Hz
1min
< 40 A/m
1.877.766.5412
X - 209

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ox 7202 iiiOx 7102 iiiOx 7104 iiiOx 7204 iii

Table of Contents