Multimeter Mode - The "Measure" Menu
Multimeter Mode (cont'd)
Single phase output
Three-phase output on
balanced network,
without a neutral
Three-phase output on
balanced network,
with a neutral
Three-phase output
3 wires
Current
measurements
can be made
with PROBIX
HX0034 clamps
and voltage
measurement
with PROBIX
HX0033.
Shop for AEMC products online at:
SCOPIX
With the POWER MEASUREMENTS option, the following measurements
are possible :
Display of the active output calculation result measured using CH1 to
measure voltage and CH2 to measure current.
The displayed value shows the three-phase active output calculated from the
selected wiring.
The displayed value is equal to 3 times the active power measured on a
phase.
Display of the three-phase active output calculation result measured by
the method using two wattmeters on a installation without a neutral.
Diagram equivalent to measurement
R
S
T
Measurement carried out with SCOPIX
R
S
T
Voltage measurement
on CH1
Current measurement
SCOPIX OX 7204
ShopAEMC
www.
W1
W2
Voltage measurement
on CH3
on CH2
.com
=
+
P
P
P
A
W
1
W
2
Current measurement
on CH4
1.877.766.5412