AEMC OX 5022B Quick Start Manual

Handscope harmonic analyzer

Advertisement

Quick Links

Quick Start Guide
ENGLISH
Handscope Harmonic Analyzer
Oscilloscope
Model OX 5022B
PORTABLE OSCILLOSCOPES
WITH AEMC
INSTRUMENTS
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OX 5022B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AEMC OX 5022B

  • Page 1 Quick Start Guide ENGLISH Handscope Harmonic Analyzer Oscilloscope Model OX 5022B PORTABLE OSCILLOSCOPES WITH AEMC INSTRUMENTS ®...
  • Page 2 Copyright Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All rights reserved. © ® ® No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into any other language) without prior agreement and written consent from Chauvin Arnoux , Inc., as governed by United States and International copyright laws.
  • Page 3: Statement Of Compliance

    Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met the instrument’s published specifications.
  • Page 4 (Note: Color of replacement leads (2) Black Test Probe Cat. #5000.97 are solid red & solid black) (1) US Wall Plug, OX 5022B / OX 5042B (1) USB Cable + Driver Cable - Replacement USB Adapter 5 V Cat. #2135.41 Cat.
  • Page 5 Example: hardwired equipment in fixed installation and circuit breakers. CAT II: Corresponds to measurements performed on circuits directly connected to the electrical distribution system. Example: measurements on household appliances and portable tools. Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 6: Precautions For Use

    When handling the sensors or test probes, do not place your fingers beyond ■ the physical guard. ■ If the battery housing cover is absent, damaged or incorrectly positioned, the instrument must not be used other than to adjust the sensors. Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 7: Power Supply

    (in mA·h) as those shipped with the oscilloscope. To remove the battery cover, use a coin to turn the slot on the back of the unit counter-clockwise. Description The Handscope Oscilloscope Model OX 5022B combines three instruments into one: 20 MHz oscilloscope ƒ...
  • Page 8: Channel Isolation

    600 V CAT III reduces the operating range to the lower voltages and/or categories. The oscilloscope is rated 600 V CAT III; at least 600 V CAT III accessories must be used Measurement Terminals Input Channel B External Input power Channel A supply Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 9: Control Features

    Adjustment of values in the secondary menus ■ Horizontal movement in a dialog box ENTER ■ Opens a dialog box from a main menu or a secondary menu ■ Validation of the items in a dialog box Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 10 Displays the main Trigger menu ■ Displays the main Tools menu ■ Displays the main Acquisition menu ■ Displays the main Memory menu ■ Displays the main Measurement/Cursor menu ■ Displays the Help window Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 11 Digital Ground Analog Ground NOTE: To prevent electric shocks or possible fires, never use accessories on which the casing is accessible if it has a voltage of >30 V compared to the ground. Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 12 Turn the screw in either direction until the signal is horizontal and looks like the screen to the left. Your probe is now calibrated. Turn the BNC base again to close access to the adjustment screw and replace the battery cover. Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 13: Remote Programming

    (603) 742-2346 E-mail: repair@aemc.com (Or contact your authorized distributor.) Contact us for the costs for repair, standard calibration, and calibration traceable to N.I.S.T. NOTE: You must obtain a CSA# before returning any instrument. Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 14: Technical Assistance

    Instruments, not by the distributor from whom it was ® purchased. This warranty is void if the unit has been tampered with, abused, or if the defect is related to service not performed by AEMC Instruments. ® Full warranty coverage and product registration is available on our website at www.aemc.com/warranty.html...
  • Page 15: Warranty Repairs

    Phone: (800) 945-2362 (Ext. 360) / (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend that you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. Handscope Harmonic Analyzer Oscilloscope Model OX 5022B...
  • Page 16 07/23 99-MAN 100597 v00 AEMC Instruments ® 15 Faraday Drive • Dover, NH 03820 USA Phone: (603) 749-6434 • (800) 343-1391 • Fax: (603) 742-2346 www.aemc.com © 2023 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All Rights Reserved. ® ®...

Table of Contents