Bamu Configuration; Additional Actual Values 2 - ABB ACS880 Firmware Manual

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
162.116 Data set 20 data
val 1
0...65535
162.117 Data set 20 data
val 2
0...65535
162.118 Data set 20 data
val 3
0...65535
162.119 Data set 22 data
val 1
0...65535
162.120 Data set 22 data
val 2
0...65535
162.121 Data set 22 data
val 3
0...65535
162.122 Data set 24 data
val 1
0...65535
162.123 Data set 24 data
val 2
0...65535
162.124 Data set 24 data
val 3
0...65535
191

191 BAMU configuration

191.30
BAMU 1 channel
0...65535
192
192 Additional actual
values 2
192.40
U phase current 2
-30000.0...
30000.0 A
192.41
V phase current 2
-30000.0...
30000.0 A
192.42
W phase current 2
-30000.0...
30000.0 A
Description
Defines the raw data to be received in data set 20 data word
1.
Raw data to be received in data set 20 data word 1.
Defines the raw data to be received in data set 20 data word
2.
Raw data to be received in data set 20 data word 2.
Defines the raw data to be received in data set 20 data word
3.
Raw data to be received in data set 20 data word 3.
Defines the raw data to be received in data set 22 data word
1.
Raw data to be received in data set 22 data word 1.
Defines the raw data to be received in data set 22 data word
2.
Raw data to be received in data set 22 data word 2.
Defines the raw data to be received in data set 22 data word
3.
Raw data to be received in data set 22 data word 3.
Defines the raw data to be received in data set 24 data word
1.
Raw data to be received in data set 24 data word 1.
Defines the raw data to be received in data set 24 data word
2.
Raw data to be received in data set 24 data word 2.
Defines the raw data to be received in data set 24 data word
3.
Raw data to be received in data set 24 data word 3.
Configuration of the measuring board (BAMU-1x).
Defines the channel of the BAMU-1x board. Fiber optic
connectors of the BAMU-1x board are connected to the first
free channel on the BCU control unit.
For single modules with 3-phase modulator, the value of this
parameter is 2. For two modules with 6-phase modulator,
the value of this parameter is 3.
0 = Not in use.
Channel.
Actual values for the additional phases of the 6-phase
modulator.
U phase current [A] of the second DC/DC converter module
in case of 6-phase modulator.
U phase current.
V phase current [A] of the second DC/DC converter module
in case of 6-phase modulator.
V phase current.
W phase current [A] of the second DC/DC converter module
in case of 6-phase modulator.
W phase current.
Parameters 141
Def/FbEq16
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
-
1 = 1
0
-
-
1 = 1 A
-
1 = 1 A
-
1 = 1 A

Hide quick links: