ABB ACS880 Firmware Manual page 146

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

146 Parameters
No.
Name/Value
196.61
User data logger
status word
Bit
Name
0
Running
1
Triggered 1 = The user data logger has been triggered. The bit is cleared when the
2
Data
available
3
Configured 1 = The user data logger has been configured. Note that the bit is not
4...15 Reserved
0000b...1111b
196.63
User data logger
trigger
Off
On
Other
196.64
User data logger
start
Off
On
Other
196.65
Factory data logger
time level
500us
2ms
10ms
196.100 Change user pass
code
10000000...
99999999
196.101 Confirm user pass
code
10000000...
99999999
Description
Provides status information on the user data logger (see
page 176).
Description
1 = The user data logger is running. The bit is cleared after the post-trigger
time has passed.
logger is restarted.
1 = The user data logger contains data that can be read. Note that the bit
is not cleared because the data is saved to the memory unit.
cleared because the configuration data is saved to the memory unit.
User data logger status word.
Triggers, or selects a source that triggers, the user data
logger.
0.
1.
Source selection (see
45).
Starts, or selects a source that starts, the user data logger.
0.
1.
Source selection (see
45).
Selects the sampling interval for the factory data logger (see
page 176).
500 microseconds.
2 milliseconds.
10 milliseconds.
(Visible when user lock is open)
To change the current user pass code, enter a new code
into this parameter as well as
code. A warning will be active until the new pass code is
confirmed. To cancel changing the pass code, close the
user lock without confirming. To close the lock, enter an
invalid pass code in parameter
parameter
196.08 Control board
See also section
User lock
New user pass code.
(Visible when user lock is open)
Confirms the new user pass code entered in
Change user pass
code.
Confirmation of new user pass code.
Terms and abbreviations
Terms and abbreviations
196.101 Confirm user pass
196.02 Pass
code, activate
boot, or cycle the power.
(page 44).
196.100
Def/FbEq16
0000b
1 = 1
Off
0
1
on page
-
Off
0
1
on page
-
500us
500
2000
10000
10000000
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents