ABB ACS880 Firmware Manual page 145

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
196.24
Full days since 1st
Jan 1980
1...59999
196.25
Time in minutes
within 24 h
1...1439 min
196.26
Time in ms within
one minute
0...59999 ms
196.29
Time source status
Bit
Name
0
Time tick received
1
Aux Time tick received
2
Tick interval is too long
3
DDCS controller
4
Master/Follower
5
Reserved.
6
D2D
7
FbusA
8
FbusB
9
EFB
10
Ethernet
11
Panel link
12
Ethernet tool link
13
Parameter setting
14
RTC
15
Drive On-Time
0000h...FFFFh
Description
Number of full days passed since beginning of the year
1980.
This parameter, together with
24 h
and
196.26 Time in ms within one minute
possible to set the date and time in the converter via the
parameter interface from a fieldbus or application program.
This may be necessary if the fieldbus protocol does not
support time synchronization.
Days since beginning of 1980.
Number of full minutes passed since midnight. For example,
the value 860 corresponds to 2:20 pm.
See parameter
196.24 Full days since 1st Jan
Minutes since midnight.
Number of milliseconds passed since last minute.
See parameter
196.24 Full days since 1st Jan
Number of milliseconds since last minute.
Time source status word.
This parameter is read-only.
Description
1 = 1st priority tick received: Tick has been received from 1st
priority source.
1 = 2nd priority tick received: Tick has been received from 2nd
priority source.
1 = Yes: Tick interval too long (accuracy compromised).
1 = Tick received: Tick has been received from an external
controller.
1 = Tick received: Tick has been received through the
master/follower link.
1 = Tick received: Tick has been received through the drive-to-
drive link.
1 = Tick received: Tick has been received through fieldbus
interface A.
1 = Tick received: Tick has been received through fieldbus
interface B.
1 = Tick received: Tick has been received through the
embedded fieldbus interface.
1 = Tick received: Tick has been received through the Ethernet
port on type BCU control unit.
1 = Tick received: Tick has been received from the control
panel, or Drive composer PC tool connected to the control
panel.
1 = Tick received: Tick has been received from Drive
composer PC tool through an FENA module.
1 = Tick received: Tick has been set by parameters
96.24...96.26.
1 = RTC time in use: Time and date have been read from the
real-time clock.
1 = Drive on-time in use: Time and date are displaying drive
on-time.
Time source status word 1.
196.25 Time in minutes within
makes it
1980.
1980.
Parameters 145
Def/FbEq16
-
1 = 1
0 min
1 = 1
0 ms
1 = 1
-
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents