Ddcs Communication - ABB ACS880 Firmware Manual

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
160

160 DDCS communication

160.41
Ext IO com port
No connect
Slot 1A
Slot 2A
Slot 3A
Slot 1B
Slot 2B
Slot 3B
RDCO CH 0
160.51
DDCS controller port
No connect
Slot 1A
Slot 2A
Slot 3A
Slot 1B
Slot 2B
Slot 3B
RDCO CH0
160.52
DDCS controller
node address
1...254
160.55
DDCS controller HW
connection
Ring
Star
160.57
DDCS controller link
control
1...15
Description
DDCS communication configuration.
Selects the channel used for connecting an optional FEA-03
extension adapter.
None (communication disabled).
Channel A on FDCO module in slot 1 (with ZCU control unit
only).
Channel A on FDCO module in slot 2 (with ZCU control unit
only).
Channel A on FDCO module in slot 3 (with ZCU control unit
only).
Channel B on FDCO module in slot 1 (with ZCU control unit
only).
Channel B on FDCO module in slot 2 (with ZCU control unit
only).
Channel B on FDCO module in slot 3 (with ZCU control unit
only).
Channel 0 on RDCO module (with BCU control unit only).
Selects the DDCS channel used for connecting an external
controller (such as an AC 800M).
None (communication disabled).
Channel A on FDCO module in slot 1 (with ZCU control unit
only).
Channel A on FDCO module in slot 2 (with ZCU control unit
only).
Channel A on FDCO module in slot 3 (with ZCU control unit
only).
Channel B on FDCO module in slot 1 (with ZCU control unit
only).
Channel B on FDCO module in slot 2 (with ZCU control unit
only).
Channel B on FDCO module in slot 3 (with ZCU control unit
only).
Channel 0 on RDCO module (with BCU control unit only).
Selects the node address for communication with the
external controller. No two nodes on-line may have the
same address.
Node address.
Selects the topology of the fiber optic link.
The devices are connected in a ring topology. Forwarding of
messages is enabled.
The devices are connected in a star topology (for example,
through a branching unit). Forwarding of messages is
disabled.
Defines the light intensity of the transmission LED of RDCO
module channel CH0. (This parameter is effective only
when parameter
160.51 DDCS controller port
RDCO
CH0. FDCO modules have a hardware transmitter
current selector.)
In general, use higher values with longer fiber optic cables.
The maximum setting is applicable to the maximum length
of the fiber optic link.
Light intensity.
Parameters 133
Def/FbEq16
No connect
0
1
2
3
4
5
6
13
No connect
0
1
2
3
4
5
6
11
1
1 = 1
Star
0
1
10
is set to
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents