118 Parameters
No.
Name/Value
133.52
Value counter 1
function
Bit
Function
0
Counter mode
0 = Loop: If warning is enabled by bit 1, it stays active only for 10 seconds
1 = Saturate: If warning is enabled by bit 1, it stays active until reset
1
Warning enable
0 = Disable: No warning is given when the limit is reached
1 = Enable: A warning is given when the limit is reached
2...15
Reserved
0000h...FFFFh
133.53
Value counter 1
source
Not selected
Other
133.54
Value counter 1
divider
0.001 ...
2147483.647
133.55
Value counter 1
warning select
Value 1
133.60
Value counter 2
actual
-2147483008 ...
2147483008
133.61
Value counter 2 limit
-2147483008 ...
2147483008
Description
Configures value counter 1. The counter calculates its
actual value (133.53) by integrating the monitored value
(133.xx) with respect to time. A divisor may be applied to the
count (see
133.54 Value counter 1
When the actual value exceeds the limit set by parameter
133.51 Value counter 1
133.55 Value counter 1 warning select
by this parameter).
The signal is sampled at 1-second intervals. Note that the
scaled (see the "Def/FbEq16" column at the signal in
question) value is used.
The current value of the counter is readable from parameter
133.50 Value counter 1
status
indicates that the count has exceeded the limit.
Value counter 1 configuration word.
Selects the signal to be monitored by value counter 1.
None.
The value is taken from another parameter.
Divisor for value counter 1. The value of the monitored
signal is divided by this value before integration.
Divisor for value counter 1.
Selects the warning message for value counter 1.
Pre-selectable warning message for value counter 1.
Reading of value counter 2. Can be reset from the Drive
composer PC tool, or from the control panel by keeping
Reset depressed for over 3 seconds.
Reading of value counter 2.
Sets the warning limit for value counter 2.
Warning limit for value counter 2.
divider).
limit, the warning specified by
is given (if enabled
actual. Bit 4 of
133.01 Counter
Def/FbEq16
00b
1 = 1
Not selected
0
-
1.000
1 = 1
Value 1
4
-
1 = 1
0
1 = 1