Load Analyzer - ABB ACS880 Firmware Manual

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
133.62
Value counter 2
function
Bit
Function
0
Counter mode
0 = Loop: If warning is enabled by bit 1, it stays active only for 10 seconds
1 = Saturate: If warning is enabled by bit 1, it stays active until reset
1
Warning enable
0 = Disable: No warning is given when the limit is reached
1 = Enable: A warning is given when the limit is reached
2...15
Reserved
0000h...FFFFh
133.63
Value counter 2
source
Not selected
Other
133.64
Value counter 2
divider
0.001 ...
2147483.647
133.65
Value counter 2
warning selection
Value 2
136

136 Load analyzer

136.01
PVL signal
Zero
DC voltage
Other [bit]
136.02
PVL filter time
0.00 ... 120.00 s
Description
Configures value counter 2. he counter calculates its actual
value (133.63) by integrating the monitored value (133.xx)
with respect to time. A divisor may be applied to the count
(see
133.64 Value counter 2
When the actual value exceeds the limit set by parameter
133.61 Value counter 2
133.65 Value counter 2 warning selection
enabled by this parameter).
The signal is sampled at 1-second intervals. Note that the
scaled (see the "FbEq" column at the signal in question)
value is used.
The current value of the counter is readable from parameter
133.60 Value counter 2
status
indicates that the count has exceeded the limit.
Value counter 2 configuration word.
Selects the signal to be monitored by value counter 2.
None.
The value is taken from another parameter.
Divisor for value counter 2. The value of the monitored
signal is divided by this value before integration.
Divisor for value counter 1.
Selects the warning message for value counter 2.
Pre-selectable warning message for value counter 2.
Peak value and amplitude logger settings.
See also section
Load analyzer
Selects the signal to be monitored by the peak value logger.
The signal is filtered using the filtering time specified by
parameter
136.02 PVL filter
The peak value is stored, along with other pre-selected
signals at the time, into parameters 136.10...136.15.
The peak value logger can be reset using parameter
Reset
loggers. The date and time of the last reset are stored
into parameters
136.16
None (peak value logger disabled).
DC voltage,
101.01 DC voltage
Source selection (see
Terms and abbreviations
13).
Peak value logger filtering time. See parameter
signal.
Peak value logger filtering time.
divider).
limit, the warning specified by
is given (if
actual. Bit 5 of
133.01 Counter
(page 40).
time.
and
136.17
respectively.
136.01 PVL
Parameters 119
Def/FbEq16
00b
1 = 1
Not selected
0
-
1.000
1 = 1
Value 2
5
136.09
0
1
on page
-
2.00 s
100 = 1 s