ABB ACS880 Firmware Manual page 72

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

72 Parameters
No.
Name/Value
114.06
DI delayed status
0000b...1111b
114.06
DIO delayed status
0000h...FFFFh
114.08
DI filter time
0.8 ... 100.0 ms
114.09
DIO1 configuration
Input
Output
114.10
DIO1 filter gain
7.5 us
195 us
780 us
4.680 ms
114.11
DIO1 output source
Not energized
Energized
Other [bit]
Description
(Visible when
114.01 Module 1 type
Displays the delayed status of the digital inputs on the
extension module. The word is updated only after
activation/deactivation delays (if any are specified).
Bit 0 indicates the status of DI1.
Note: The number of active bits in this parameter depends
on the number of digital inputs on the extension module.
Example: 0101b = DI1 and DI3 are on, remainder are off.
This parameter is read-only.
Delayed status of digital inputs.
(Visible when
114.01 Module 1 type
Displays the status of the digital input/outputs on the
extension module. This word is updated only after
activation/deactivation delays (if any are specified).
Bit 0 indicates the status of DIO1.
Note: The number of active bits in this parameter depends
on the number of digital input/outputs on the extension
module.
Example: 0000001001 = DIO1 and DIO4 are on, remainder
are off.
This parameter is read-only.
Delayed status of digital input/outputs.
(Visible when
114.01 Module 1 type
Defines a filtering time for parameter
Filtering time for 114.05.
(Visible when
114.01 Module 1 type
Selects whether DIO1 of the extension module is used as a
digital input or output.
DIO1 is used as a digital input.
DIO1 is used as a digital output.
(Visible when
114.01 Module 1 type
Determines a filtering time for DIO1 when it is used as an
input.
7.5 μs.
195 μs.
780 μs.
4.680 ms.
(Visible when
114.01 Module 1 type
Selects a signal to be connected to digital input/output DIO1
of the extension module when parameter
configuration
is set to Output.
Output is not energized.
Output is energized.
A specific bit in another parameter.
= FDIO-01)
=
FIO-01
or FIO-11)
= FDIO-01)
114.05 DI
status.
=
FIO-01
or FIO-11)
= FIO-11)
=
FIO-01
or FIO-11)
114.09 DIO1
Def/FbEq16
-
1 = 1
-
1 = 1
10.0 ms
10 = 1 ms
Input
0
1
7.5 us
0
1
2
3
Not energized
0
1
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents