ABB ACS880 Firmware Manual page 53

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
106.11
Main status word
0000h...FFFFh
106.16
Status word 1
Bit
Name
0
Enabled
1
Inhibited
2
Reserved
3
Reserved
4
Reserved
5
Started
6
Reserved
7
Reserved
8
Local control
9
Network control
10
Ext1 active
11
Ext2 active
12
Charging
13...15
Reserved
0000h...FFFFh
Description
Main status word of the DC/DC converter unit.
Reflects the status of the DC/DC converter unit irrespective
of control source eg, a fieldbus system, control panel
(keypad), PC tool, standard I/O, application program or
sequence programming, and irrespective of actual control
profile which is used to control the DC/DC converter unit.
This parameter is read-only.
The bit assignments are shown in the table below. For
detailed bit descriptions, see page 196.
Bit
Name
0
Ready to switch ON
1
Ready run
2
Ready ref
3
Tripped
4
-
5
-
6
-
7
Warning
8
Operating
9
Remote
10
Ready for load
11
User bit 0
12
User bit 1
13
User bit 2
14
Charging
15
User bit 3
Main status word.
Status word 1 of the DC/DC converter unit.
This parameter is read-only.
Description
1 = Run enable and start enable signals are present
1 = Start inhibited
1 = DC/DC converter has been started
1 = DC/DC converter is in local control
1 = DC/DC converter is in network control
1 = Control location Ext1 active
1 = Control location Ext2 active
1 = Charging relay is closed
Status word 1.
Parameters 53
Def/FbEq16
-
1 = 1
-
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents