Binding Members to the Stack
Assigning a Stack Backup Switch
224
CN4093 Application Guide for N/OS 8.3
You can bind Member switches to a stack csnum using either their asnum or
chassis UUID and bay number:
CN 4093(config)# stack switch-number <csnum> universal-unic-id <chassis UUID>
CN 4093(config)# stack switch-number <csnum> bay <bay number (1-4)>
-or-
CN 4093(config)# stack switch-number <csnum> bind <asnum (1-16)>
To remove a Member switch, execute the following command:
CN 4093(config)# no stack switch-number <csnum>
To bind all units of a stack, use the command:
CN 4093(config)# stack bind
The stack bind command automatically assigns switch numbers to all attached
switches in the stack that do not yet have a number assigned.
To define a Member switch as a Backup (optional) which will assume the Master
role if the Master switch fails, execute the following command:
CN 4093(config)# stack backup <csnum>
-or-
CN 4093(config)# stack bind