Binding Members to the Stack

Assigning a Stack Backup Switch

262
G8264CS Application Guide for ENOS 8.4
You can bind Member switches to a stack csnum using either their asnum or MAC 
address :
RS 8264CS(config)# stack switch-number <csnum> mac <MAC address>
‐or‐
RS 8264CS(config)# stack switch-number <csnum> bind <asnum>
To remove a Member switch, execute the following command:
RS 8264CS(config)# no stack switch-number <csnum>
To bind all units of a stack, use the command:
RS 8264CS(config)# stack bind
The stack bind command automatically assigns switch numbers to all attached 
switches in the stack that do not yet have a number assigned.
To define a Member switch as a Backup (optional) which will assume the Master 
role if the Master switch fails, execute the following command:
RS 8264CS(config)# stack backup <csnum>