MA lighting dot2 User Manual page 30

Hide thumbs Also See for dot2:
Table of Contents

Advertisement

dot2 User Manual - What are...
Version 1.5 – 2018-11-29
English
A different option when we store is Cue Only. If we use that option and store fixture 1 at 40% in cue 5 you'll see
that we didn't make a change in cue 6. meaning it still looks the same as it did before we stored cue 5.
Cue
number
1
2
3
4
5
6
If you add a fixture that hadn't previously been used, then the dot2 can automatically create a hidden cue
number zero and put the default value (the value a fixture has if it isn't told anything) in that cue. Cue Zero can be
activated in the
Settings view
You can't access this cue, but it makes sure that cues look correct if you copy them.
Have a look at this example:
Cue
number
1
2
3
4
5
6
Here we have fixture 1 that has a stored values in cue number 2. This value tracks from this cue and to cue 6. If
you copy cue number 1 to a new cue 3.5 using cue only, then you'll see that the fixture has 0% in the new cue and
goes back to 50% in cue 4 - so cue number 4 has never changed.
Cue
number
1
2
3
3.5
4
5
© 2018 MA Lighting Technology GmbH - Dachdeckerstr. 16 - 97297 Waldbüttelbrunn - Germany
Phone +49 5251 688865-27 - support@ma-dot2.com - www.malighting.com
Fixture 1
Dim
50
50
60
60
40
60
for a cue list.
Fixture 1
Dim
0
50
50
50
50
50
Fixture 1
Dim
0
50
50
0
50
50