7.5.5 Combined Setting of Voltage and Current Setting

The APPLy subsystem provides a command that enables you to set the current and
voltage of a channel in one step.
The combined voltage and current setting command takes approximately 100 ms, i.e.
longer than the setting of a single value.
APPLy
APPLy <voltage> [,<current>][,<output>]
APPLy?
Sets/Queries the voltage and current value of the selected channel.
Parameters:
<voltage>
User Manual 1178.8736.02 ─ 02.01
DOWN
Decrease resistance by a defined step size.
Increment: 0.1 ohms
Default unit: ohms
MIN | MAX
Return minimum or maximum resistance value.
See
Example "Configuring the resistance limit"
OFF | ON | 0 | 1
OFF | 0
Deactivates constant resistance mode.
ON | 1
Activates constant resistance mode.
See
Example "Configuring the resistance limit"
............................................................................................................................ 97
numeric | MIN | MAX | DEFault
numeric
Numeric value for voltage in the range of 0.000 to 20.000.
MIN
Min voltage at 0.000 V.
MAX
Max value for voltage at 20.000V.
Remote Control Commands
Configuration Commands
on page 96.
on page 96
97