Combined Setting Of Voltage And Current Setting - R&S NGM202 User Manual

Hide thumbs Also See for NGM202:
Table of Contents

Advertisement

®
R&S
NGL200/NGM200
Query parameters:
<resistance>
Example:
[SOURce:]RESistance:STATe <state>
[SOURce:]RESistance:STATe?
Sets or queries the constant resistance mode.
Parameters:
<state>
Example:

7.5.6 Combined Setting of Voltage and Current Setting

The APPLy subsystem provides a command that enables you to set the current and
voltage of a channel in one step.
The combined voltage and current setting command takes approximately 100 ms, i.e.
longer than the setting of a single value.
APPLy
APPLy <voltage> [,<current>][,<output>]
APPLy?
Sets or queries the voltage and current value of the selected channel.
Parameters:
<voltage>
User Manual 1178.8736.02 ─ 06
DOWN
Decreases resistance by a defined step size.
Increment: 0.1 ohms
Default unit: ohms
MIN | MAX
Returns minimum or maximum resistance value.
See
Example "Configuring the resistance limit"
OFF | ON | 0 | 1
OFF | 0
Deactivates constant resistance mode.
ON | 1
Activates constant resistance mode.
See
Example "Configuring the resistance limit"
.......................................................................................................................... 109
numeric | MIN | MAX | DEFault
numeric
Numeric value for voltage in the range of 0.000 to 20.050.
MIN
Min voltage at 0.000 V.
MAX
Max value for voltage at 20.050V.
Remote Control Commands
Configuration Commands
on page 108.
on page 108
109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ngm200 seriesNgl200 seriesNgl-com2aNgl201Ngl202Ngm201

Table of Contents