4.3 Trying Out the Instrument

4.3.1 Selecting the Channels

4.3.2 Setting the Output Voltage and Current Limit

4.3.3 Activating the Channels Output

4.3.4 Storing/Recalling of Instrument Settings

User Manual 5601.1343.02 ─ 02
This chapter describes some basic functions that you can perform with the R&S
NGE100B.
To select a channel, press the corresponding channel key. The key illuminates.
To set the output voltage and current limit via Live-Mode:
1. Long press the rotary knob to enter into editing mode.
The channel 1 voltage is highlighted in blue.
2. Move to the desired parameter via the arrow keys.
3. On the desired parameter, rotate the knob to adjust its value.
Alternatively:
1. Press Voltage or Current key on the front panel.
2. Press the desired channel key to activate the respective voltage or current limit set-
ting for that channel. The value on the respective channel becomes editable and
the digit for adjustment is indicated by a blue cursor.
3. Press the right or left arrow key to move the cursor.
4. Press the up/down arrow key or turn the rotary knob to change the value of the
digit indicated by the cursor. The new value registers immediately.
The output voltages can be switched on or off irregardless of the operating mode the
instrument is in.
To activate the channel output, press Output key on the front panel followed by the
desired channel key or vice versa. The font color of that channel section changes to
green or red depending on the operating mode the instrument is in.
The instrument settings can be stored in the instrument memory by long pressing
Store Recall key and selecting the memory location key (M1 to M5). The previous set-
ting is overwritten.