Trying out the instrument

This chapter describes some basic functions that you can perform with the
R&S NGL/NGM.
Source and sink current
The R&S NGL/NGM power supply series are 2 quadrant power supplies
which may both source and sink current. When the voltage across the out-
put terminal exceeds the set voltage, current flows into the instrument. The
default behavior "Auto" can be configured in output menu, see section "Out-
put mode" in the User Manual.
On the display, sink mode is shown as negative current. See also
mode"
on page 27.
7.1

Setting the output voltage and current

1. Press [Home] key.
The R&S NGL/NGM displays the home window.
2. Select voltage or current parameter in the home window.
The R&S NGL/NGM displays an on-screen keypad to set the value.
3. Enter the required value.
4. Confirm value with the unit key (V/mV or A/mA).
See
"Source and sink current"
ing modes supported in different models.
7.2

Activating the channels output

The output voltages can be switched on or off regardless of the instrument's oper-
ating mode.