Measurement Commands - R&S NGL200 series User Manual

Hide thumbs Also See for NGL200 series:
Table of Contents

Advertisement

®
R&S
NGL200

7.6 Measurement Commands

The MEASure subsystem provides commands to query the voltage and current values
of a channel.
MEASure[:SCALar]:CURRent[:DC]?
MEASure[:SCALar]:ENERgy?
MEASure[:SCALar]:ENERgy:RESet
MEASure[:SCALar]:ENERgy:STATe
MEASure[:SCALar]:POWer?
MEASure[:SCALar][:VOLTage][:DC]?
MEASure[:SCALar]:CURRent[:DC]?
Queries the currently measured current of the selected channel.
Example:
Usage:
MEASure[:SCALar]:ENERgy?
Queries the measured the current released energy value of the previous selected
channel. Please notice that the energy meter has to be activated to measure the cur-
rent released energy value.
Example:
Usage:
MEASure[:SCALar]:ENERgy:RESet
Resets the energy counter for the selected channel.
Usage:
MEASure[:SCALar]:ENERgy:STATe <state>
MEASure[:SCALar]:ENERgy:STATe?
Activates/Deactivates or Queries the energy counter for the selected channel.
Parameters:
<state>
User Manual 1178.8736.02 ─ 02.01
.................................................................................112
......................................................................................... 112
................................................................................. 112
................................................................................. 112
........................................................................................... 113
............................................................................... 113
MEAS:CURR? -> 1.000E +00
Query only
MEAS:ENER? -> 5.382E+00 (value in Wh)
Query only
Event
OFF | ON | 0 | 1
ON |1
Activates the energy counter.
OFF | 0
Deactivates the energy counter.
Remote Control Commands
Measurement Commands
112