Radiator/Condenser Cooling Fan Motor - Suzuki Ignis Service Manual

Rg413
Table of Contents

Advertisement

• Tighten receiver/dryer cap to specified torque
Tightening torque
Receiver / dryer cap : 13 N·m (1.3 kg-m, 9.5 lb-ft)
• Replenish specified amount of compressor oil to compressor
suction side by referring to "REPLENISHING COMPRES-
SOR OIL" in this section.
RADIATOR/CONDENSER COOLING FAN
MOTOR
REMOVAL AND INSTALLATION
For details, refer to "RADIATOR" in Section 6B.
INSPECTION
1) Check continuity terminal "a" – "b" and "c" – "d" about the

radiator/condenser cooling fan motor (1).

If check results are no continuity, replace radiator/condenser
cooling fan motor.
2) Check no continuity "a" – "c" and "b" – "d" about the radiator/
condenser cooling fan motor (1).
If check result are continuity, replace radiator/condenser
cooling fan motor.
3) Connect battery to radiator/condenser cooling fan motor ter-
minal "a" – "b" and "c" – "d" as shown in figure, then check
that the radiator/condenser cooling fan motor operates
smoothly.
Reference current of radiator/condenser cooling fan
motor at 12 V
"a" – "b" : 7.8 – 11.8 A
"c" – "d" : 4.8 – 8.8 A
AIR CONDITIONING (OPTIONAL) 1B-31

Advertisement

Table of Contents
loading