INSPECT POWER SUPPLY CIRCUIT OF SAS
CONTROL MODULE (TERMINAL 1W)
Turn the ignition switch to LOCK position.
•
Disconnect the negative battery cable and wait for
•
1 min or more .
Connect all SAS control module connectors.
•
Connect the driver and passenger-side
•
pre-tensioner seat belt connectors.
Connect the driver and passenger-side curtain air
•
bag module connectors.
Connect the driver and passenger-side side air bag
•
module connectors.
Connect the passenger-side air bag module
•
connector.
Connect the clock spring connector.
•
Inspect the voltage for PID/DATA monitor
•
RCM_VOLT item using WDS or equivalent.
Is the voltage of at least one terminal 9 V or more
•
?
INSPECT WIRING HARNESS BETWEEN BATTERY
AND FUSE BLOCK
Connect the negative battery cable.
•
7
Turn the ignition switch to ON position.
•
Measure the voltage at instrument cluster connector
•
terminal 1G.
Is the voltage 9 V or more ?
•
VERIFY THAT SAS CONTROL MODULE
CONNECTOR TERMINAL 1X IS GROUND
8
Turn the ignition switch to LOCK position.
•
No Go to the next step.
Yes Go to the next step.
Repair the wiring harnesses, then go
No
to Step 9.
Replace the SAS control module, then
go to the next step.
Yes
(See SAS CONTROL MODULE
REMOVAL/INSTALLATION )
(w)
RX-8 Safety
Page 29