Mounting/Installation
Note
During mounting ensure that the housing tamper
switch (1) definitely has contact with the wall.
Ensure that the bottom part and the integrated
components are not damaged when the screws
are tightened and that all screws are screwed in
completely.
6.
Mount the bottom part of the housing to the wall.
7.
Connect the mains connection properly while it is
disconnected from the power supply.
8.
Install the strain relief clamp.
9.
Connect the network cable to the socket on the PCB.
10. Place the battery (or batteries) in the battery com-
partment.

Connecting the components

On alarm panels in general
Incorrect or unclean installation work may lead to
erroneous interpretation of signals and therefore
false alarms.
The costs incurred by potential dispatches of res-
cue services, such as the fire service or police,
must be borne by the operator of the system. For
this reason, read these instructions carefully and
ensure that lines and components used are la-
belled precisely when the system is installed.
11. Connect all components to the terminal blocks.
12. Ensure that all connections are securely fitted.
Important note:
Please note that bare wire ends must not come into
contact with conducting surfaces or contacts on the
PCBs.
Therefore, insulate all unused stripped wire ends as
required.

Installing an optional wireless mobile module

If available:
Plug the wireless mobile module into the terminal block
(CON 7 GSM/GPRS) on the PCB. Ensure that no elec-
tronic components are damaged or touched if possible.
(See also the installation instructions for the respective
wireless mobile module.)