Abus SECVEST FUAA50 Series Installer Manual page 79

Table of Contents

Advertisement

Type
A/C fault
Ext PSU Fault
Ext PSU Low Volts
General Fault
Fault comm. path
Full Set Ready
Explanation
The output is activated when the alarm panel does not
have voltage OR any zone with type "Ext PSU A/C fault"
is triggered.
The delay until this output is activated depends on the
value set under "System -> A/C Fault Delay (minutes)".
Note
The system is VdS compliant if you use this output type
for signalling an AC fault.
The output is activated when an external power supply de-
tects a fault and reports the fault using zone type "Ext
PSU Fault".
The output is only deactivated when the fault is corrected
and the user confirms the alarm with a valid code on the
alarm panel.
The output is activated when an external power supply de-
tects a correspondingly low voltage using zone type "Ext
PSU Low Volts".
The alarm panel deactivates the output as soon as the
zone is reset and the user confirms the fault with a valid
code.
The output is activated as soon as an event occurs that
causes a fault.
This includes:
 RF Low Battery
 RF Supervision
 RF Jamming
 A/C fault
 Battery Fault
 Ext PSU Fault
 Tamper Activated
Note that in the event of an A/C Fault the output is already
activated a few seconds after the fault is detected and is
NOT influenced by the set delay time.
Danger
The system is no longer VdS compliant if you use this
output type to signal an AC Fault.
Use this to signal an AC Fault type to be VdS compliant.
The output is activated as soon as the alarm panel identi-
fies a fault in the communication method and is deac-
tivated when the fault no longer exists.
This output is activated when the partition is ready to be
armed.
Configuration
Can be assigned
to partitions
No
No
No
Yes
No
Yes
79