Abus SECVEST FUAA50 Series Installer Manual page 69

Table of Contents

Advertisement

5.
Select WAM Info.
6.
Select WAM 1.
Note
When the wireless universal module is taught in,
its configuration is also transferred, so it is possi-
ble to see under "WAM Info" which function the
wireless universal module had when it was taught
in.
Role
Explanation
Not
The wireless universal module is not
used
taught in.
1 Wireless Re-
Received wireless signals from
peater
taught-in wireless detectors (taught
into the WAM) are forwarded to the
alarm panel. No further settings are
necessary here.
2 Output Module
Up to four relays of the WAM can be
activated by the wireless alarm panel
according to the configuration.
3 T/R Module
Zone and output module for connec-
tion of wired detectors (flood detec-
tors) or a block lock/key switch.
4 Sounder Module For connection of a wired external
sounder or compact alert.
WAM as wireless repeater (WAM function 1)
If the wireless universal module is taught in with the wire-
less repeater function, the wireless detectors with signals
that this module should transmit should also be taught
into the WUM.
See the instructions for the wireless universal module
(WUM) for this.
WAM as output module (WAM function 2)
Note
If the wireless universal module is taught in with
the output function, the alarm panel automatically
reserves the corresponding outputs in the panel
for this module.
Note
These outputs no longer have to be added manu-
ally.
Simply define the settings for the output function
as described in section Editing outputs.
These outputs only need to be configured but no
longer have to be added.
See the instructions for the universal accessory
module (WUM) for this.
WAM as zone and output module (WAM function 3)
Note
If the wireless universal module is taught in with
function 3, the alarm panel automatically reserves
the corresponding zone and outputs in the panel
for this module.
Input 1 and input 2 form the wired zone of the WAM.
Input 1 functions as the connection for the alarm loop.
Input 2 functions as the connection for the tamper
zone.
Both of these connections correspond to the associ-
ated wireless zone.
During wiring see the instructions for the wireless uni-
versal module (WUM) for this.
WAM as sounder module (WAM function 4)
If the WAM is configured as a sounder module, a display
appears upon connection, where you have to configure
the partitions for which the sounder will be activated. This
setting is defined similarly to the setting for the external
siren.
The connection of the compact alert in the WUM can be
found in the instructions for the wireless universal module
(WUM).
Note
Ensure that the voltage-free outputs on the WAM
can be loaded with max. 500 mA at 24 volts.
These outputs are optocouplers with a forward re-
sistance of 2 Ω.
Delete All
1.
Select Delete All.
2.
Confirm the selection with Next.
3.
Confirm the security prompt with Yes to delete the
WAM or Back if you are not sure.
Configuration
69