Configuration
Sounder On
Siren On
Confirmation Time
(for confirmation modeDD243
and BS8243 only.)
Entry Keypad Lock
(for confirmation mode DD243
and BS8243 only.)
Unconfirmed Reset
128
o
Note: Confirmed panic alarm is not available in the basic confirma-
tion mode.
 DD243
 BS8243
Note
The DD243 and BS8243 settings are only relevant for the UK (United Kingdom).
When selecting these options, detailed knowledge of these guidelines is required.
Dropdown selection field for:
 Unconfirm
o
The system is armed. The alarm panel will now arm all internal
sounders when an unconfirmed alarm occurs.
 Confirm
o
The system is armed. The alarm panel will now not arm any internal
sounders until a confirmed alarm occurs.
Note
The alarm panel does not allow the following configuration:
Siren on – confirm and sirens on – do not confirm
Dropdown selection field for:
 Unconfirm
o
The alarm panel triggers the external sirens for all alarms and over-
rides any siren delay.
 Confirm
o
The system is armed. The alarm panel will now not arm any sirens
until a confirmed alarm occurs.
Note
The alarm panel does not allow the following configuration:
Siren on – do not confirm and sirens on – confirm
Input field for the confirmation time for burglar alarms in minutes. The confirmation
time can be set to between 1 and 60 minutes.
Note
Confirmation times < 30 minutes do not meet the requirements set out in DD243
and BS8243.
Enabled
The user must disarm the system using an alternative device (not control device or
alarm system), e.g. a remote control or key switch (relevant for DD243 and
BS8243).
Deactivated
The user can disarm the system by entering their access code on the keypad (on
control device or alarm system) after the entrance door has been opened (relevant
for DD234).
Dropdown selection field for:
 Installer