Abus SECVEST FUAA50 Series Installer Manual page 76

Table of Contents

Advertisement

Configuration
4.
Confirm the selection once the configuration is com-
plete by selecting Submit.
Type
not used
Intruder alarm
Conf. Intruder alarm
Burg Confirm Timer
Perimeter Warning
Panic alarm
HUA Confirm
76
Explanation
This output is not used and not activated at any time.
This output is activated when one of the following zone
types or events is triggered and the system is armed:
 Normal Alarm
 Tamper (only when system is armed)
 Entry Route
 Tamper zone (only when system is armed)
 Entry delay expired
 24 Hour Alarm (only when system is armed)
This type only functions when confirmation mode BS8243
is selected under "System -> Confirmation".
A confirmed burglar alarm has occurred (normal alarm).
The alarm panel activates the output when:
 two "normal alarms" are triggered in the same partition
during the confirmation time
 a "normal alarm" and a tamper alarm are triggered in
the same partition during the confirmation time.
This output type can be used for one or more partitions.
Note that "normal alarms" and tamper alarms must be lo-
cated in the same partition as the output.
The output is deactivated when a user resets the system.
This output is activated while the timer for confirmation of
a burglar alarm is running and is deactivated as soon as
the timer stops.
The output is activated when a perimeter warning is trig-
gered.
This output is activated when a hold up alarm is triggered. Yes
A confirmed hold up alarm has occurred.
The alarm panel activates the output under the following
conditions:
 Users trigger an alarm at at least two different hold up
transmitters during the hold up confirmation time.
 A hold up transmitter is activated and a tamper alarm of
a hold up transmitter is triggered during the confirmation
time.
This output type can be assigned to one or more parti-
tions. Note that the hold up transmitter (and tamper
alarms) must be assigned to the same partition.
The output is deactivated as soon as a user resets the
system.
Can be assigned
to partitions
Yes
Yes
Yes
No
Yes
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents