Abus SECVEST FUAA50 Series Installer Manual page 77

Table of Contents

Advertisement

Type
HUA Confirm Timer
Duress Code
Confirmed Alarm
Fire
Technical Alarm
24 hours)
Zone Alarm
External Siren
Internal Siren
External Strobe
Internal Strobe
Alarm Abort
Explanation
This output is activated while the timer for confirmation of
a hold up alarm is running and is deactivated as soon as
the timer has expired.
A duress code has been used. The alarm panel activates
the output as soon as a user enters a duress code and
deactivates the output again when the user resets the
system.
This output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated again when the alarm is
confirmed.
This output is activated when a fire alarm is triggered.
This output is activated when a zone with the attribute
"Technical Alarm" triggers an alarm. It is only deactivated
again when the zone triggering the alarm is reset (cause
for the technical alarm has been corrected) AND the user
confirms the technical alarm on the alarm panel with a
valid code.
This output is activated when a zone with the attribute "24
Hour Alarm" triggers an alarm.
This output is activated when the selected zone reports
an alarm and is deactivated again when the alarm is re-
set.
This output is activated when there is a local alarm in the
selected partition for the set siren time of the external si-
ren.
The output does not activate for a technical alarm or hold
up alarm.
This output is activated when there is a local alarm in the
selected partition for the set siren time of the internal si-
ren.
The output does not activate for a technical alarm or hold
up alarm.
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the parti-
tion has been successfully armed if the EXTERNAL
strobe signal for confirmation has been activated.
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the parti-
tion has been successfully armed if the INTERNAL strobe
signal for confirmation has been activated.
The output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated as soon as the alarm is
confirmed.
Configuration
Can be assigned
to partitions
No
Yes
Yes
yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
77