Configuration
Name/function
Force Set
Remote Unset Full Set
Remote Unset Part Set
136
Explanation (checkbox)
A user can be permitted to arm the alarm panel using the remote control even if one
or more zones are not working or are open.
Note
If Force Set is enabled, the system is no longer compliant with EN 50131.
Dropdown selection field for:
 Off
 The user cannot force the system to arm with the remote control even if the
corresponding zones have been given attribute "Force Set".
 Confirm
 The user can force the system to arm with the remote control. To do so, pro-
ceed as follows:
1. The user presses the "arm" button on the remote control.
2. The system does not start arming.
3. The user presses the same button on the remote control again to confirm
that the system should arm.
 On
 The user only has to press the corresponding button on the remote control
once to start the arming process.
Note
With the "Confirm" and "On" options, the user is also permitted to arm the system
with the remote control even if it would need to be reset after an alarm.
Select whether armed partitions can only be disarmed using the remote control
when the delay time has been started beforehand ("Final Door" zone is triggered).
Dropdown selection field for:
 Always
 The user can always disarm the possible partitions without the entry time being
started first.
 During entry time
 The user must first open a "Final Door" zone. This starts the entry delay. The
user can now disarm the possible partitions.
 Partitions for which no entry delay has started remain armed.
Select whether internally armed partitions can only be disarmed using the remote
control when the delay time has been started beforehand ("Final Door" zone is trig-
gered).
Dropdown selection field for:
 Always
 The user can always disarm the possible partitions without the entry time being
started first.
 During entry time
 The user must first open a "Final Door" zone. This starts the entry delay. The
user can now disarm the possible partitions.
 Partitions for which no entry delay has started remain armed.