Name/function
Supervision
Explanation (checkbox)
Dropdown selection field for alarm system response for supervision
If a wireless detector has had no contact with the alarm control panel for more than
20 min, the alarm panel creates a log entry: "RF warning". The alarm panel also
prevents the system from being armed. If a user overrides this warning and arms
the alarm panel, the log entry "RF warning overridden" is generated.
If a wireless detector has had no contact with the alarm panel for more than 2 h,
corresponding processes are activated as follows:
Alarm panel is armed
Disabled
No response
Log book entry of this
Fault
event
No display and no warning
tones
"RF Supervision" or "RF Fault"
outputs are activated
Tampering alarm
Tamper Ac-
Supervision is reported
tivated
Note:
If "Tamp as Tamp-Only" is disa-
bled, the "Supervision" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
Note
The "Tamper" option is required in Grade 2 systems in order to comply with
EN 50131-1:2006+A1:2009.
If the "Tamper" option is used along with the following setting:
System -> User Reset -> System Tampers = No
the user cannot reset the system.
Configuration
Alarm panel is disarmed
No response
Log book entry of this event
Display and warning tones
"RF Supervision" or "RF Fault"
outputs are activated
Tampering alarm
Supervision is reported
Note
If "Tamp as Tamp-Only" is disa-
bled, the "Supervision" or "Fault"
outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm" is
sent.
133