Abus SECVEST FUAA50 Series Installer Manual page 220

Table of Contents

Advertisement

Configuration
Outputs
Prox Tag
Remote controls
220
Repeat door locks
You can find the signal strength of the received messages from the door locks on
the repeater here.
Radio Outputs
 Use this option to check all configured radio outputs.
Wired Outputs
 Use this option to check all configured wired outputs.
After exiting the menu, all outputs switch back to their basic configured state.
Testing of chip keys is carried out in the web interface in the same manner as on the alarm
panel.
Move the Prox Tag across the reader area at the bottom of the alarm panel (where the ABUS
logo is).
The following information appears on the display:
 which user is assigned to this Prox Tag or
 that the Prox Tag is not recognised by the alarm panel.
Testing of the remote control is carried out in the web interface in the same manner as on the
alarm panel.
Press a button on the remote control.
The following information appears on the display:
 the consecutive number of the remote control
 a letter or character corresponding to the pressed key
A = "arm" key (closed lock)
* =
"internally arm" key or key for activating a "User Defined" output (*)
? =
"query status" key (?)
D = "disarm" key (open lock)
 which user is assigned to this remote control
 the function of the pressed button
- Set All
- Prt Set All or Output On (Off or Toggle) xyz
- Query Status
- Unset All
 the received signal strength (RSSI)
Example
Remote 001,D:User 002
Complete disarming
RSSI: 9