Name/function
Ctrl Device Unset Full Set
Ctrl Device Unset Part Set
Auto Rearm
Explanation (checkbox)
Select whether armed partitions can only be disarmed using the wireless control
device when the delay time has been started beforehand ("Final Door" zone is trig-
gered).
Dropdown selection field for:
 Always
 The user can always disarm the possible partitions without the entry time being
started first.
 During entry time
 The user must first open a "Final Door" zone. This starts the entry delay. The
user can now disarm the possible partitions.
 Partitions for which no entry delay has started remain armed.
Select whether internally armed partitions can only be disarmed using the wire-
less control device when the delay time has been started beforehand ("Final
Door" zone is triggered).
Dropdown selection field for:
 Always
 The user can always disarm the possible partitions without the entry time being
started first.
 During entry time
 The user must first open a "Final Door" zone. This starts the entry delay. The
user can now disarm the possible partitions.
 Partitions for which no entry delay has started remain armed.
Appears when the following is set:
System->Confirmation->Confirmation Mode->Basic
Select how often the system automatically rearms after the siren time has expired.
Dropdown selection field for:
 Never
 The alarm panel never rearms. The alarm panel switches to the alarm status
just one time.
 1 x, 2 x, 3 x, 4 x, 5 x
 Always
he system rearms all closed zones but not the detectors still sending alarm
T
signals.
 One of these settings is required in order to comply with EN 50131.
 If the system is rearmed, an acoustic internal alarm instead of the normal entry
tone is generated by the wireless alarm panel if a user enters through the entry
route.
Configuration