Appendix
Click on "Check for upgrade?"
If the FTP server replies to this question with a "Yes", the following pop-up menus appear.
Note
The current software comprises a new application file and language file. These files are stored on the SD card.
Click on "Restart the alarm panel".
The alarm panel installs the new files and performs a reboot.
Important
SW >= 3.00.06, saving and restoring the configuration
Before the alarm panel starts the upgrade, the configuration files and the SSL certificate are saved automatically on
the internal flash drive. The new software is then installed, and the alarm panel restarted. At this point, the factory set-
tings are used first, but the alarm panel then automatically reproduces the configuration files and the SSL certificate
from the flash drive (as if the configuration had been saved/reproduced manually). This means that the Start Wizard is
not used, the SSL certificate is not regenerated and, more importantly, that the installer does not have to go to the site
in order to respond to the command prompt of the Start Wizard.