Table 2 CID report groups – CID codes
CID report group
Fire
Panic alarm
Panic alarm
Panic alarm
Medical Alarm
Medical Alarm
Intruder alarm
Intruder alarm
Intruder alarm
Technical Alarm
Tampers
Tampers
Set/Unset
Set/Unset
Part set
Part set
Reset
Exit Timeout
Omit
CID code
Contains:
110
Fire Alarm and Fire Restore
120
Hold Up zone (Panic) and Restore
Hold Up (Panic) silent and Restore
Hold Up keypad (Panic) and Restore
Hold Up RF (Panic) and Restore
Hold Up wireless control panel (Panic) and Restore
121
Duress Code alarm
129
Hold Up (Panic) alarm acknowledged
100
Medical alarm
101
Social Care (Social Emergency)
130
Intrusion Alarm and Intrusion Restore
139
Alarm confirmation
406
Alarm Abort
150
Technical alarm and Restore
137
Alarm control panel housing front tampering and Restore
Keypad tampering and Restore
Detector tampering and Restore
Control panel tampering and Restore
Bell tampering and Restore
Wireless control panel tampering and Restore
External Sirens tampering and Restore
WAM tampering and Restore
Door Lock tampering and Restore
461
4 incorrect User Codes entered one after the other (also known as "User Code
Tampering")
401
System or partition armed and disarmed
409
System or partition armed and disarmed with key switch
401
System or partition armed internally
409
System or partition armed internally with key switch
305
System or partition reset
457
Exit Timeout and Restore
573
User/system zone hidden, zone shown