Abus SECVEST FUAA50 Series Installer Manual page 138

Table of Contents

Advertisement

Configuration
Name/function
Silence Alerts
(silent warnings)
Abort time
Siren Delay (User)
Entry Alarm Delay
138
Explanation (checkbox)
This option controls the length of time in which warning tones (a brief "beep" every
few minutes) are sounded.
Dropdown selection field for:
 User Code
 Warnings are sounded until a user enters their code to confirm the warning.
 30 minutes
 60 minutes
 120 minutes
 Warnings are sounded for the set amount of time. The warning tones can be
stopped by entering a user code.
 No alert tones
 No acoustic alerts are sounded.
Note
The alarm panel does not display any warnings as long as a partition is still armed.
Input field for the alarm abort time in seconds (value between 0 and 120).
The alarm panel always starts this time when an alarm has been triggered. If a user
mutes the alarm during this time, no installer reset is required.
If an alarm occurs and a user disarms the system within this time, "Alarm Abort"
outputs are activated and an alarm abort is reported.
"Siren Delay (User)" in minutes (value between 0 – 10).
0 means disarmed.
Note
When "Siren Delay (User-based)" is enabled (> 0), the entire behaviour of the siren
delay is blocked in the partition settings.
This does not comply with EN 50131.
ARC communication and Confirmation Mode affect the siren delay in the partition
settings.
Note
Siren Delay (User) only affects the outdoor sirens.
Note
In the event of a fire, intruder or 24h alarm, there is no siren delay (user)
Additional delay when deviating from the entry route.
Select whether the user is permitted an additional time of 30 seconds when deviat-
ing from the entry route, before an external alarm is started.