Configuration
Name/function
Unset Comms
Burg
Comms
Rearm
Dynamic Auto Report
Telecoms Priority
170
Explanation (checkbox)
Enabled
The alarm system transmits all status messages to the ARC, regardless of whether
the system is armed or disarmed.
Deactivated
The alarm system transmits tamper, network failure and other status messages to
the ARC while it is armed. When disarmed, the status messages are not transmitted
to the ARC.
Only appears when "System Confirmation Confirmation Mode = Basic" and
"Communications Protocol = Fast Format")
Enabled
The alarm system activates channel 3 again as soon as the siren time has ex-
pired. After channel 3 has been reactivated, an event can be transmitted again if it
occurs. The system automatically omits triggered zones in this case.
Note: if a "Final Door" zone is triggered, channel 3 is activated at the end of the
configured entry/exit time.
Deactivated
Channel 3 remains activated until a user or installer resets the system.
Enabled
The dynamic test call is activated.
Deactivated
The dynamic test call is deactivated. The "Static Test Call" dropdown selection field
appears.
Set the order in which the communication methods should be used here.
Ethernet / IP
1, 2, 3 or No
Mobile
PSTN
1, 2, 3 or No
GSM/mobile
1, 2, 3 or No
Note:
The alarm control panel automatically uses the IP-based protocol DC-09 if the alarm
control panel uses Ethernet (LAN) as an outgoing communication path.
In doing so, the data from traditional protocols are packed into IP packages and
transferred.
For details, see the "ARC/ESCC reporting protocols" appendix
S/W >=3.00.05
Set the order in which the communication methods should be used here.
Ethernet / IP
1, 2, 3 or No
Mobile
Note
means data transfer according to the setting via IP gateway the "IP
Mobile Setup" menu
PSTN
1, 2, 3 or No
Mobile
1, 2, 3 or No
Note
means classic voice transmission (also DTMF and FSK) or SMS
transmission via a wireless mobile network.