Abus SECVEST FUAA50 Series Installer Manual page 92

Table of Contents

Advertisement

Configuration
Name/function
Exit Time [s]
Entry Time [s]
Alarm Response
Siren Delay [min] (ARC)
92
Explanation
This option only appears for modes "Timed Set" and "Silent Set".
Time for the exit delay in seconds
The exit time can be any value between 10 s and 120 s.
Time for the entry delay in seconds
The entry time can be any value between 10 s and 120 s.
Select the response here for when an alarm occurs in this partition.
Internal
 Alarm panel, indoor siren, info module and control device.
Siren
 Alarm panel, indoor siren, info module and control device.
 External Sirens
Sirens and ESCC reporting
 Alarm panel, indoor siren, info module and control device.
 External Sirens
 Communication with ARC/ESCC
A siren delay only goes into effect for alarm response "Siren + Comms".
Strobe
 Alarm panel, indoor siren, info module and control device.
 Outdoor sirens (with STROBE only)
Strobes and ESCC reporting
 Alarm panel, indoor siren, info module and control device.
 Outdoor sirens (with STROBE only)
Communication with ARC/ESCC
Note
This does not affect the voice dialler, text message, email and push notification
communication methods.
Time for the delay duration of the siren(s).
The siren delay can be set to a value between 0 and 10 min.
When an alarm has been triggered the alarm panel waits until this time has expired
before it activates the sirens.
Note
The siren delay only goes into effect when the alarm response includes comms.
The siren delay does not go into effect when a comms fault occurs.
The siren delay will not be active when "Installer Mode->System->Confirmation-
>Confirmation Mode->DD243 or BS8243" and "Installer Mode->System->Confirma-
tion->Siren On ->Unconfirm" are set.
If sounders are assigned to multiple partitions, the alarm panel uses the shortest si-
ren delay set for the partitions in question.
Note
If under System -> Security, "Siren Delay (user-based)" is enabled (> 0), this menu
item does not appear here.
And the entire behaviour of the siren delay (ARC) is blocked!