Configuration
Activity
The function of the detector is reversed
Mon.
(inverted). This should only be used in
connection with the social care emer-
gency call.
An alarm is triggered on the alarm panel
when the detector does not register any
alarm within a certain time period.
Note
The Soak Test function should only be set if a de-
tector tends to trigger false alarms.
This function works automatically. To test the
range of the detector, use the "walk test" function
56
and do not activate the soak test, as this function
stops the detector from triggering any alarms
when the wireless alarm system is armed and
only saves a message to the memory instead.
After 14 days the wireless alarm system resets
the zone and brings it back to normal operation.
Note
The Force SetOmit function must also still be ac-
tivated in menu System -> Security Settings ->
Force Set.