Name/function
Settle time [s]
Exit Time [s]
Entry Time [s]
Alarm Response
Explanation
This option only appears for modes "Final Door Set", "Lock Set" and "Exit Termi-
nate".
Use this option to define a time delay so that detectors can settle before the partition
is internally armed.
This may be necessary if detectors have triggered, send an alarm signal and have
still not been reset.
During this time the alarm panel ignores alarm signals from detectors and sirens are
not triggered.
Enter the time in seconds as a 2-digit number: 01–30. The factory default for the
settle time is 15 s.
In this time the wireless PIRs located at the exit which have triggered can settle and
be reset.
This option only appears for modes "Timed Set" and "Silent Set".
Time for the exit delay in seconds.
The exit time can be any value between 10 s and 120 s.
Time for the entry delay in seconds.
The entry time can be any value between 10 s and 120 s.
Select the response here for when an alarm occurs in this partition.
Internal
 Alarm panel, indoor siren, info module and control device.
Siren
 Alarm panel, indoor siren, info module and control device.
 External Sirens
Sirens and ESCC reporting
 Alarm panel, indoor siren, info module and control device.
 External Sirens
 Communication with ARC/ESCC
A siren delay only goes into effect for alarm response "Siren + Comms".
Strobe
 Alarm panel, indoor siren, info module and control device.
 Outdoor sirens (with STROBE only)
Strobes and ESCC reporting
 Alarm panel, indoor siren, info module and control device.
 Outdoor sirens (with STROBE only)
Communication with ARC/ESCC
Note
This does not affect the voice dialler, text message, email and push notification
communication methods.
Configuration
101