Abus SECVEST FUAA50 Series Installer Manual page 280

Table of Contents

Advertisement

Appendix
Extended SIA 3
Extended SIA 3 V2
Extended SIA 3 V3
Whereby:
AAAAAA
"N"
"ti"hh:mm/
"id"nnn/
"ri"nn/
CC
cc
"A"S
Note:
The alarm control panel sends
table above.
Example
The different formats for the SIA protocol appear as follows in the event of a fire alarm in zone 2 of partition 4 at 10:15
with the account number 10 for partition 4:
SIA1
SIA2
SIA3
Extended SIA3
Extended SIA3 V2
Extended SIA3 V3
Note about Extended SIA3 V2:
Some S/W versions that work in the SIA recipients do not always recognise the "/" text separator. This may cause
problems. This incorrectly results in "mains fail" messages on the ARC (ESCC). This may occur when arming or dis-
arming the alarm control panel or when entering or exiting the Installer Mode.
Therefore, in version 2 of Extended SIA3, the "/" text separator has been replaced by a "|" text separator.
For example, the string will change from:
#000010|Nti10:15/ri4/FA2/AFire Zone 2
to:
#000010|Nti10:15|ri4|FA2|AFire Zone 2
If you are having problems with incorrect"power failure" messages, try this extended SIA3 V2 option.
Note about Extended SIA3 V3:
Some S/W versions that work in the SIA recipients do not always recognise the "/" text separator. This may cause
problems.
Therefore, in version 3 of Extended SIA3, the "/" text separator has been replaced by a "^" text separator in two posi-
tions.
For example, the string will change from:
#000010|Nti10:15/ri4/FA2/AFire Zone 2
to:
#000010|Nti10:15/ri4/FA2^AFire Zone 2^
280
#AAAAAA|Ntihh:mm/idnnn/rinn/CCcc/AS
#AAAAAA|Ntihh:mm|idnnn|rinn|CCcc|AS
#AAAAAA|Ntihh:mm/idnnn/rinn/CCcc^AS^
Adjustable 6-digit account number (e.g. 123456).
New event (always N)
Time (e.g. ti10:23/).
User number, when usable, otherwise not sent (e.g. id123/ or id6/)
Partition number (e.g. ri12/ or ri3).
Event code (e.g. FA = Fire Alarm).
Zone or control panel number, when usable, otherwise not sent (e.g. 23 or 5)
Text description of the event, usually a description of the log book event
the characters that are between " and " shown above exactly as they are listed in the
#000010|NFA2
#000010|N/ri4/FA2
#000010|Nti10:15/ri4/FA2
#000010|AFire Zone 2
#000010|Nti10:15/ri4/FA2/AFire Zone 2
#000010|Nti10:15|ri4|FA2|AFire Zone 2
#000010|Nti10:15/ri4/FA2^AFire Zone 2^