Abus SECVEST FUAA50 Series Installer Manual page 224

Table of Contents

Advertisement

Configuration
Email
224
PSTN
 When this is selected, the possible configured recipients are displayed with their contact
names as stored in the phone book.
 Scroll to the desired contact. Press the "Select" or "Start" key in the web interface.
 The alarm panel sends a test text message to this recipient.
GSM / Mobile
 When this is selected, the possible configured recipients are displayed with their contact
names as stored in the phone book.
 Scroll to the desired contact. Press the "Select" or "Start" key in the web interface.
 The alarm panel sends a test text message to this recipient.
 The recipient receives an SMS in the following form:
<Home Message>: 10:56 21/01/2015 SMS Test Call
 During the test call a series of progress messages appear on the display.
 If the test call was not successful, the display shows a brief message with the
cause of the error.
Email must be activated and the contact must be saved in the phone book.
Installer Mode->Communications->Email->Call Mode->Enabled
A list of the available connected transmission paths can be seen (on WBI only):
Ethernet, Ethernet / IP Mobile
 When this is selected, the possible configured recipients are displayed with their contact
names as stored in the phone book.
 Scroll to the desired contact. Press the "Select" or "Start" key in the web interface.
 The alarm panel sends an email to this recipient.
 The recipient receives an email in the following form:
Subject:
<Home Message>: Email Test Call
Text:
<Home Message>:
11:09 21/01/2015 Email Test Call
 During the test call a series of progress messages appear on the display.
If the test call was not successful, the display shows a brief message with the cause of the
error.